Datakom DKG-307 Manual de usuario Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 29
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
DKG-307 User Manual V-01.03
(14.02.2006)
- 5 -
2. INPUTS AND OUTPUTS
RS-232 SERIAL PORT: This connector provides serial data input and output for various purposes like remote
monitoring and remote programming.
EXTENSION CONNECTOR: This connector is intended for the connection to output extension modules. The
optional relay extension module provides 8 programmable 16A relay outputs. The unit allows the use of up to
2 I/O extension modules.
Term Function Technical data Description
1 GENERATOR CONTACTOR
Relay output, 16A-AC
This output provides energy to the generator
contactor. If the generator phases do not have
acceptable voltage or frequency values, the
generator contactor will be de-energized. In
order to provide extra security, the normally
closed contact of the mains contactor should
be serially connected to this output.
2 U
3 V
4 W
Generator phase
inputs, 0-300V-AC
Connect the generator phases to these inputs.
The generator phase voltages upper and
lower limits are programmable.
5 GENERATOR NEUTRAL
Input, 0-300V-AC Neutral terminal for the generator phases.
6 MAINS NEUTRAL
Input, 0-300V-AC Neutral terminal for the mains phases.
7 T
8 S
9 R
Mains phase inputs,
0-300V-AC
Connect the mains phases to these inputs.
The mains voltages upper and lower limits are
programmable.
10 MAINS CONTACTOR
Relay output, 16A-AC
This output provides energy to the mains
contactor. If the mains phases do not have
acceptable voltages, the mains contactor will
be de-energized. In order to provide extra
security, the normally closed contact of the
generator contactor should be serially
connected to this output.
11 GROUND
O VDC Power supply negative connection.
12 BATTERY POSITIVE
+12 or 24VDC The positive terminal of the DC Supply shall
be connected to this terminal. The unit
operates on both 12V and 24V battery
systems.
13 SPARE SENDER INPUT
Input, 0-5000 ohms No connection to this terminal.
14 OIL PRESSURE SENDER
Input, 0-5000 ohms Analogue oil pressure sender connection. Do
not connect the sender to other devices. The
input has programmable characteristics and
connects to any kind of sender.
15 COOLANT TEMP. SENDER
Input, 0-5000 ohms Analogue high temperature sender
connection. Do not connect the sender to
other devices. The input has programmable
characteristics and connects to any kind of
sender.
16 CHARGE
Input and output Connect the charge alternator’s D+ terminal to
this terminal. This terminal will supply the
excitation current and measure the voltage of
the charge alternator.
Vista de pagina 4